CP665 Standard type Oilless enclosed cylinders
Top seller among oilless enclosed type pneumatic cylinders.
With its high reliability and proven performance, this cylinder meets various applications in different fields.
■CP665 Standard oilless enclosed type(Bore size:φ40~φ100)
With its high reliability and proven performance, this cylinder meets various applications in different fields.
■CP665 Standard oilless enclosed type(Bore size:φ40~φ100)
Model code | Standard oilless enclosed type |
---|---|
CP665 | |
Operation type | Double acting |
Lubricant | none (Oilless) |
Bore size(mm) | φ40,50,63,80,100 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.
CP665DR Double rod type Oilless enclosed cylinders
Double rod cylinder designed based on CP665 pneumatic cylinder.
■CP665DR Oilless enclosed / Double rod cylinder(Bore size:φ40~φ100)
■CP665DR Oilless enclosed / Double rod cylinder(Bore size:φ40~φ100)
Model code | Oilless enclosed / Double rod cylinder |
---|---|
CP665DR | |
Operation type | Double acting |
Lubricant | none (Oilless) |
Bore size(mm) | φ40,50,63,80,100 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.
MP665 Oilless enclosed cylinders with solenoid valve
CP665 oilless enclosed cylinder with directly mounted 5-port solenoid valve.
This design enables easier piping and reduction in air consumption, thus lowering costs.
■MP665 Oilless enclosed cylinders with solenoid valve(Bore size:φ40~φ100)
This design enables easier piping and reduction in air consumption, thus lowering costs.
■MP665 Oilless enclosed cylinders with solenoid valve(Bore size:φ40~φ100)
Model code | Oilless enclosed cylinders with solenoid valve | |
---|---|---|
MP665 | ||
Operation type | Double acting | |
Lubricant | none (Oilless) | |
Bore size(mm) | φ40,50,63,80,100 | |
Working pressure | 0.2~0.7MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.05MPa | |
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | |
Solenoid valve | Model code | 4A3□ |
Internal leakage | Below a specified value in JIS B8375 | |
Rated voltage | AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V | |
Allowable voltage fluctuation | ±10% of applicable voltage | |
Temperature rise | Max. 70℃ | |
Insulation class | Class B | |
Power consumption | AC:6VA DC:5.5W | |
Response time | ≦ 0.03s |
●Refer to catalog for details.
SP665 Oilless enclosed cylinders with reed switch
Oilless enclosed cylinder based on CP665 with reed switch for detecting
stroke position.
This cylinder boasts high adaptability regardless of loads or operational environment.
■SP665 Oilless enclosed cylinders with reed switch(Bore size:φ40~φ100)
This cylinder boasts high adaptability regardless of loads or operational environment.
■SP665 Oilless enclosed cylinders with reed switch(Bore size:φ40~φ100)
Model code | Oilless enclosed cylinders with reed switch |
---|---|
SP665 | |
Operation type | Double acting |
Lubricant | none (Oilless) |
Bore size(mm) | φ40,50,63,80,100 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
Switch | Model code | SW-1 | SW-2 |
---|---|---|---|
Detecting method | Proximity of iron | ||
Rated voltage | AC/DC5~115V | AC100V~220V | |
Rated current | 2~60mA | 2~30mA | |
Power rating | 3W | 6VA | |
Lamp (Leakage current) |
LED light when switch is on ( - ) |
Neon lamp light up when switch is off (1mA or less) |
|
Isolation resistance | 20M Ω Min. | ||
Withstand voltage | 1,500V / min | ||
Ambient temp | -5~50℃ | ||
Protect construction | Equivalent to IP65 | ||
Internal circuit |
●Refer to catalog for details.
MS665 Oilless enclosed cylinders with 5-port solenoid valve and reed switch
Oilless enclosed cylinders based on CP665 with 5-port solenoid valve and
reed switch.
Advantage of integration of each unit can be fully enjoyed.
■MS665 Oilless enclosed cylinders with 5-port solenoid valve and reed switch(Bore size:φ40~φ100)
Advantage of integration of each unit can be fully enjoyed.
■MS665 Oilless enclosed cylinders with 5-port solenoid valve and reed switch(Bore size:φ40~φ100)
Model code | Oilless enclosed cylinders with 5-port solenoid valve and reed switch | |
---|---|---|
MS665 | ||
Operation type | Double acting | |
Lubricant | none (Oilless) | |
Bore size(mm) | φ40,50,63,80,100 | |
Working pressure | 0.2~0.7MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.05MPa | |
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | |
Solenoid valve | Model code | 4A3□ |
Internal leakage | Below a specified value in JIS B8375 | |
Rated voltage | AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V | |
Allowable voltage fluctuation | ±10% of applicable voltage | |
Temperature rise | Max. 70℃ | |
Insulation class | Class B | |
Power consumption | AC:6VA DC:5.5W | |
Response time | ≦ 0.03s |
Switch | Model code | SW-1 | SW-2 |
---|---|---|---|
Detecting method | Proximity of iron | ||
Rated voltage | AC/DC5~115V | AC100V~220V | |
Rated current | 2~60mA | 2~30mA | |
Power rating | 3W | 6VA | |
Lamp (Leakage current) |
LED light when switch is on ( - ) |
Neon lamp light up when switch is off (1mA or less) |
|
Isolation resistance | 20M Ω Min. | ||
Withstand voltage | 1,500V / min | ||
Ambient temp | -5~50℃ | ||
Protect construction | Equivalent to IP65 | ||
Internal circuit |
●Refer to catalog for details.
CP6810(H) CP6820(H) Lightweight compact type oilless enclosed cylinders
Lightweight, compact pneumatic cylinders without tie rod mount, employing
extruded aluminum tube.
■CP6810 CP6820 Lightweight compact oilless enclosed type (standard type)(Bore size:φ40~φ100)
■CP6810H CP6820H Lightweight compact heat-resistant type(Bore size:φ40~φ100)
■CP6810 CP6820 Lightweight compact oilless enclosed type (standard type)(Bore size:φ40~φ100)
■CP6810H CP6820H Lightweight compact heat-resistant type(Bore size:φ40~φ100)
Model code | Lightweight compact oilless enclosed type (standard type) | Lightweight compact heat-resistant type |
---|---|---|
CP6810(Tye rod less type) CP6820(Tye rod type) |
CP6810H(Tye rod less type) CP6820H(Tye rod type) |
|
Operation type | Double acting | |
Lubricant | none (Oilless) | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) |
Bore size(mm) | φ40,50,63,80,100 | |
Working pressure | 0.2~1.0MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.5MPa | |
Ambient temp | -5~60℃ (The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
5~120℃ |
●Refer to catalog for details.
MP6810 MP6820 Lightweight compact type cylinders with solenoid valve
CP6810/CP6810 oilless enclosed cylinders with directly mounted 5-port
solenoid valve.
This design enables easier piping and reduction in air consumption, thus lowering costs.
■MP6810 MP6820 Lightweight compact oilless enclosed cylinders with 5-port solenoid valve(Bore size:φ40~φ100)
This design enables easier piping and reduction in air consumption, thus lowering costs.
■MP6810 MP6820 Lightweight compact oilless enclosed cylinders with 5-port solenoid valve(Bore size:φ40~φ100)
Model code | Lightweight compact oilless enclosed cylinders with 5-port solenoid valve | |
---|---|---|
MP6810(Tye rod less type) MP6820(Tye rod type) |
||
Operation type | Double acting | |
Lubricant | none (Oilless) | |
Bore size(mm) | φ40,50,63,80,100 | |
Working pressure | 0.2~0.7MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.05MPa | |
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | |
Solenoid valve | Model code | 4A3□ |
Internal leakage | Below a specified value in JIS B8375 | |
Rated voltage | AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V | |
Allowable voltage fluctuation | ±10% of applicable voltage | |
Temperature rise | Max. 70℃ | |
Insulation class | Class B | |
Power consumption | AC:6VA DC:5.5W | |
Response time | ≦ 0.03s |
●Refer to catalog for details.
SP6810 SP6820 Lightweight compact type cylinders with reed switch
Oilless enclosed cylinders based on CP6810/CP6820 with reed switch for
detecting stroke position.
■SP6810 SP6820 Lightweight compact oilless enclosed cylinders with reed switch(Bore size:φ40~φ100)
■SP6810 SP6820 Lightweight compact oilless enclosed cylinders with reed switch(Bore size:φ40~φ100)
Model code | Lightweight compact oilless enclosed cylinders with reed switch |
---|---|
SP6810(Tye rod less type) SP6820(Tye rod type) |
|
Operation type | Double acting |
Lubricant | none (Oilless) |
Bore size(mm) | φ40,50,63,80,100 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
Switch | Model code | SS-3A | SS-3B | SS-4C | SS-6W |
---|---|---|---|---|---|
Detecting method | Magnetic proximity switches | ||||
Rated voltage | Max.AC125V Max.DC100V |
Max.DC24V | AC5~220V DC5~115V |
AC5~220V DC5~125V |
|
Rated current | AC3~18mA DC3~25mA |
30~65mA | AC5~15mA DC5~20mA |
2~30mA | |
Lamp | LED light when switch is on | ||||
Isolation resistance | 100MΩ Min. | 50MΩ Min. | |||
Withstand voltage | AC1500V / min | AC1800V / min | |||
Ambient temp. | -5~60℃ | -5~120℃ | |||
Protect construction | IP67 | IP65 | Equivalent to IP65 | ||
Electrical connection | Lead wire(φ4PVC・1m) | Conduit | Terminal conduit | ||
Color of lead wire | Gray | Black | - | - | |
Internal circuit |
●Please use SS-3A series in case of low-current operation
such as sequencer. Indicator light doesn't function if SS-3B is used with
low-current operation.
●Refer to catalog for details.
●Refer to catalog for details.
SP6810H SP6820H Lightweight compact cylinders with heat-resistant reed switch
Cylinders based on CP6810H/CP6820H with heat-resistant reed switch for
detecting stroke position.
■SP6810H SP6820H Lightweight compact heat-resistant cylinders with heat-resistant reed switch(Bore size:φ40~φ100)
■SP6810H SP6820H Lightweight compact heat-resistant cylinders with heat-resistant reed switch(Bore size:φ40~φ100)
Model code | Lightweight compact heat-resistant cylinders with heat-resistant reed switch |
---|---|
SP6810H(Tye rod less type) SP6820H(Tye rod type) |
|
Operation type | Double acting |
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) |
Bore size(mm) | φ40,50,63,80,100 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | 5~120℃ |
Switch | Model code | SS-5A | SS-6W |
---|---|---|---|
Detecting method | Magnetic proximity switches | ||
Rated voltage | AC5~220V DC5~115V |
AC5~220V DC5~125V |
|
Rated current | AC5~15mA DC5~20mA |
2~30mA | |
Lamp | - | LED light when switch is on | |
Isolation resistance | 100MΩ Min. | 50MΩ Min. | |
Withstand voltage | AC1,500V / min | AC1,800V / min | |
Ambient temp. | 0~100℃ | -5~120℃ | |
Protect construction | IP65 | Equivalent to IP65 | |
Electrical connection | Lead wire(φ4PVC・Heat resistant type・3m) | Terminal conduit | |
Color of lead wire | Black | - | |
Internal circuit |
●Refer to catalog for details.
MS6810 MS6820 Lightweight compact cylinders with solenoid valve and switch
Oilless enclosed cylinders based on CP6810/CP6820 with 5-port solenoid valve
and reed switch.
Advantage of integration of each unit can be fully enjoyed.
■MS6810 MS6820 Lightweight compact oilless enclosed cylinders with 5-port solenoid valve and reed switch(Bore size:φ40~φ100)
Advantage of integration of each unit can be fully enjoyed.
■MS6810 MS6820 Lightweight compact oilless enclosed cylinders with 5-port solenoid valve and reed switch(Bore size:φ40~φ100)
Model code | Lightweight compact oilless enclosed cylinders with 5-port solenoid valve and reed switch | |
---|---|---|
MS6810(Tye rod less type) MS6820(Tye rod type) |
||
Operation type | Double acting | |
Lubricant | none (Oilless) | |
Bore size(mm) | φ40,50,63,80,100 | |
Working pressure | 0.2~0.7MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.05MPa | |
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | |
Solenoid valve | Model code | 4A3□ |
Internal leakage | Below a specified value in JIS B8375 | |
Rated voltage | AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V | |
Allowable voltage fluctuation | ±10% of applicable voltage | |
Temperature rise | Max. 70℃ | |
Insulation class | Class B | |
Power consumption | AC:6VA DC:5.5W | |
Response time | ≦ 0.03s |
Switch | Model code | SS-3A | SS-3B | SS-4C | SS-6W |
---|---|---|---|---|---|
Detecting method | Magnetic proximity switches | ||||
Rated voltage | Max.AC125V Max.DC100V |
Max.DC24V | AC5~220V DC5~115V |
AC5~220V DC5~125V |
|
Rated current | AC3~18mA DC3~25mA |
30~65mA | AC5~15mA DC5~20mA |
2~30mA | |
Lamp | LED light when switch is on | ||||
Isolation resistance | 100MΩ Min. | 50MΩ Min. | |||
Withstand voltage | AC1500V / min | AC1800V / min | |||
Ambient temp. | -5~60℃ | -5~120℃ | |||
Protect construction | IP67 | IP65 | Equivalent to IP65 | ||
Electrical connection | Lead wire(φ4PVC・1m) | Conduit | Terminal conduit | ||
Color of lead wire | Gray | Black | - | - | |
Internal circuit |
●Please use SS-3A series in case of low-current operation
such as sequencer. Indicator light doesn't function if SS-3B is used with
low-current operation.
●Refer to catalog for details.
●Refer to catalog for details.